III – The axes’ parameters
S900–II CAN and AXES Configuration
Version 2.0 |–>
III – 3. 2. Analogue measured axes parameters
PARAMETER
Abbreviation Description Criterion Corresponding value and function
1319
1331
TYP_AXE_A1
TYP_AXE_A2
Definition of the type of
analogue axis followed.
Measurement type
0 = No analogue axis.
1 = Position measurement.
2 = Speed measurement.
Measurement direction
0 = Counting increases.
256 = Counting decreases
Bipolarity of analogue symbol Not used, leave at 0.
The value of the parameter is the sum of the values selected for each of the Criteria.
Default value :
0
Possible value : 0 –> 65535 Interaction with other parameters :
PARAMETER Abbreviation Description Parameter
value
Corresponding function
1320
1332
CONVERS_A1
CONVERS_A2
Conversion coefficient of the
voltage received in
millimetres.
1 –> 25000
Value that represents the variation in mm/mVolts of the axes’ board’s analogue
input for a movement of 100 mm of the measured axis.
d = total distance covered in mm
Dv = input voltage variation on 3 axes board in mV.
This parameter equals Dv * 100 / d
Default value :
0
Possible value : 1 –> 25000 Interaction with other parameters : 1322–1324, 1334–1336
1322
1334
KPULSES_A1
KPULSES_A2
Conversion multiplier factor.
1 –> 10000
Value used to readjust the value of parameter 1320 when it exceeds 25 000.
Conversion factor applied = parameter 1320 * parameter 1322 / 100
Default value :
0
Possible value : 1 –> 10000 Interaction with other parameters : 1320–1324, 1332–1336