III – The axes’ parameters
S900–II CAN and AXES Configuration
Version 2.0 |–>
III – 3. The measured axes
III – 3. 1. Numeric measured axes’ parameters
See the “Mould chasing” manual for more details.
PARAMETER
Abbreviation Description Criterion Corresponding value and function
1290
TYP_AXE_N1
TYP_AXE_N2
Definition of the type of
numeric axis followed.
Type of measurement
0 = No numeric axis.
1 = Position measurement.
_
_
Direction of measurement
0 = Counting increases.
4 = Counting decreases
Type of axis
0 = no initialization, no modulo.
8 = no initialization, modulo.
16 = with initialization, no modulo.
24 = with initialization, modulo
Type of initialization
0 = Initialization on cam and Init pulse.
32 = Initialization on cam only.
The value of the parameter is the sum of the values selected for each of the Criteria.
Default value :
0
Possible value : 0 –> 65535 Interaction with other parameters :
PARAMETER Abbreviation Description Parameter
value
Corresponding function
1291
1305
NUM_AXE_N1
NUM_AXE_N2
Output port associated with
the axis
1 –> 6
Number of the output port associated with the measured axis.
. 1 to 3 for axes board 1 (1 = J6, 2 = J7, 3 = J8)
. 4 to 6 for axes board 2 (4 = J9, 5 = J10, 6 = J11)
Default value :
0
Possible value : 1 –> 6 Interaction with other parameters : 611, 747, 883, 1019, 1155