II – Command and visualisation devices
S900–II USER MANUAL
Version 2.1 |–>
12
01T01518_1
25.11.99
II – 3. IMM restart box (BRP)
This small box is a simplified version of the pendant which enables IMM cycles to be restarted without
having to use the pendant.
Figure 15 : IMM restart box (BRP)
The keys on the BRP have the same functions as the corresponding keys on the pendant, except for
the
key. This key cannot be used to cancel faults apart from the “Part grip” fault.
The robot state is shown by indicator lights :
green light : IMM cycle authorised,
yellow light : “Without robot” mode
red light : Fault. If the key remains inactive, read the instructions on the pendant
display
In an emergency, use the closest “Emergency stop” button, which in fact will be that of the IMM
control as the BRP box is installed next to it.
Note : The BRP commands can be integrated into the IMM’s control cabinet. In this case, other
commands are available. Consult the “S900–II commands integrated into the Injection Moulding
Machine” manual.