Programming S900II Level 1
Version 2.2 |>
IV Programming instructions
52
01T01527_2
25.5.00
IV 5. 4. L and R labels
Accessible using
then or :
Syntax : L01 to L99
Syntax : R00 to R99
Note : . The label L00 is not valid.
. The L labels are unique, the Rs can be multiple.
. They can ONLY be used in the MAIN program, (therefore not in the SP, SR etc....).
(See paragraph III 2. page 23).
IV 5. 5. END of PRG, SP..., SR, PLC codes
Syntax : END
This code is automatically added to the end of each PRG, SP, SR et PLC when is
pressed. You cannot delete it.
It is always possible to insert steps before the step containing the word END.