I – Parameter definition
S900–II Configuration
Version 2.1
11
01T01506_1
25.11.99
PARAMETER Abbreviation Description Parameter
value
Corresponding function
0008
TIMOUT_PP
Value of part grip Time–Out
in 1/10 seconds
0 –> 999 If the robot parameters are set with the IMM interface (parameter No. 171
= 1 or 2), a special delay is applied to the part grip in the IMM. (So that the
IMM is not open for too long).
After this delay, the robot executes an automatic home return if the part pres-
ence control is not activated.
If the value P8 > P6 then P6 has priority
Default value :
30
Possible value :
0 –> 999
Interaction with other parameters : 6, 171
0009
TYP_ALARM
Type of alarm signal 0 The alarm output (parameter 553) flashes.
Alarm OUT 000
Normal
status
Fault period
1
The alarm output (parameter 553) is the complement of the fault output
(parameter 552).
Fault OUT 001
Alarm OUT 000
1
0
1
0
Step by Step / Auto
and Stop mode
Adjust mode
Period when the robot is in fault mode = Alarm
Default value :
0
Possible value :
0 –> 1
Interaction with other parameters : 552, 553