MPA–II v2 Fault messages
V 1.0 |–>
11
01T01995_0
6.4.00
CPU BOARD UNSERVICEABLE:SERIOUS FAULT Nº63
Counting initialization fault.
CPU BOARD UNSERVICEABLE:SERIOUS FAULT Nº64 IT PIT fault.
SERIOUS FAULT: DANGER, EMERGENCY STOP
CIRCUIT NOT WORKING CORRECTLY
One of the emergency stop serial contacts is open and the 24S is still present. Is PF
an isolated contact ? Check the interface wiring.
SERIOUS FAULT: CHECK THE SAFEGUARD
CIRCUIT AND VALIDATION BUTTON
If the key is not in the “maintenance” position, the BVAL input cannot be present.
Cabling error or a fault from the keyboard or the serial link board.
Test page 9 –> NMTN and BVAL
FAULT: MOVEMENT TOWARDS MACHINE
PROHIBITED IN WITHOUT ROBOT MODE
In this mode, the robot must remain in the Outside Machine area.
FAULT: WITHOUT ROBOT MODE
MOVE THE ROBOT OUT OF THE MACHINE
...In Adjust mode for example
FAULT: PREMATURE ANTICIPATED RESTART
CHECK LENGTH OF THE DELAY
The mould movement start time is maybe unstable. This delay must be set during
automatic operation.
FAULT: PREMATURE ANTICIPATED RESTART
CHECK THE SAFETY MARGIN
The mould movement start time is maybe unstable. This duration must be changed
in the program options.
–> Programming, RESET, etc.
ROBOT MOVES INTO THE MACHINE TOO EARLY
check destination position
Programming error ?
ROBOT MOVES INTO THE MACHINE TOO EARLY
the Machine Open instruction is missing
Programming error ?