Conair MPW Guía de usuario Pagina 58

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 60
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 57
Corporate Office: 724.584.5500 Instant Access 24/7 (Parts and Service): 800.458.1960 Parts and Service: 814.437.6861
53
Problem PossibleCause Solution
Erratictemperature
control
Lowcoolantflowthroughevaporator Adjustflowtoproperlevel
Intermittentoverloadingofchillercapacity Checktomakesurechillerisproperlysized
forprocessload
Hotgasbypassvalve Contactrefrigerationservicetechnician
Temperaturesensor Replaceiffaulty
Insufficientcooling
(temperature
continuestorise
abovesetpoint)
Processloadtoohigh Checktomakesurechillerisproperlysized
forprocessload
Coolantflowthrough evaporatortoohighorlow Adjustflowtoproperlevel
Insufficientcondensercooling See“HighRefrigerantPressure”
Hotgasbypassvalvestuckopen Contactrefrigerationservicetechnician
Refrigerationcircuitproblem Contactrefrigerationservicetechnician
Temperaturesensor Replaceiffaulty
Drawings
Wehavepreparedacustomsetofdrawingsforyourunitandplacedtheminsidethecontrol
panelpriortoshipment.Pleaserefertothesedrawingswhentroubleshooting,servicing,and
installingtheunit.Ifyoucannotfindthesedrawingsorwishtohaveadditional copies,please
contactourServiceDepartmentandreferencetheserialnumberofyourunit.
ContactConairPartsandServiceat18004581960(intheUnitedStates)or18144376861
(international).Press1forServiceand2forParts.

Vista de pagina 57
1 2 ... 53 54 55 56 57 58 59 60

Comentarios a estos manuales

Sin comentarios