One Conair Drive ● Pittsburgh, PA 15202 ● 412-312-6000 ● FAX 412-312-6227 ● www.conairnet.com
TPHS017/1101
SPECIFICATIONS
TEMPERATURE CONTROL UNITS
Thermolator
®
vacuTrac (VTR1-DI and VTR2-DI)
Positive/Negative Pressure
VTR1-DI (single zone) VTR2-DI (dual zone)
VTR1-DI rear view and connections
MODELS
VTR1-DI VTR2-DI
Performance Characteristics
Minimum setpoint 32 °F {0 °C} 32 °F {0 °C}
Maximum setpoint 180 °F {82 °C} 180 °F {82 °C}
Pump Performance per zone
Pump Size Hp {kW} 2 {1.49} 3 {2.24} 5 {3.73} 7.5 {5.59} 2 {1.49} 3 {2.24} 5 {3.73} 7.5 {5.59}
Nominal flow gpm {l/min}
55 {208} 80 {303} 100 {379} 115 {435} 55 {208} 80 {303} 100 {379} 115 {435}
Pressure @ nominal flow psi {bar}
31 {2.2} 35 {2.5} 43 {3} 51 {3.6} 31 {2.2} 35 {2.5} 43 {3} 51 {3.6}
Dimensions inches {mm}
A -Height
43 {1090} 43 {1090}
B- Width
14 {355} 28 {710}
C- Depth
31.5 {800} 31.5 {800}
Weight Ib {kg}
Operating
300 {136} 305 {138} 310 {141} 320 {145} 600 {272} 610 {277} 620 {281} 640 {290}
Shipping
470 {213} 475 {216} 480 {218} 490 {222} 770 {349} 780 {354} 790 {358} 810 {367}
Water Connections NPT inches (Female)
To/From Process 1.25 1.25
Cooling Water Inlet/Outlet 0.75 0.75
ELECTRICAL REQUIREMENTS - full load amps
†
VTR1-DI VTR2-DI
Heater 9 kW 12 kW 9 kW 12 kW
Voltage
208V 230V 460V 575V 208V 230V 460V 575V 208V 230V 460V 575V 208V 230V 460V 575V
Pump sizes
2 Hp {1.49 kW} 31.8 28.8 14.4 11.5 40.2 36.4 18.2 14.6 63.6 57.6 28.8 23.0 80.4 72.8 36.4 29.1
3 Hp {2.24 kW} 34.7 31.4 15.7 12.6 43.1 39.0 19.5 15.6 69.3 62.8 31.4 25.1 86.1 78.0 39.0 31.2
5 Hp {3.73 kW} 38.5 34.8 17.4 13.9 46.8 42.4 21.2 17.0 76.9 69.9 34.8 27.8 93.7 84.8 42.4 33.9
7.5 Hp {5.59 kW} 45.7 41.4 20.7 16.6 54.1 49.0 24.5 19.6 91.5 82.8 41.4 33.1 108.3 98.0 49.0 39.2
SPECIFICATIONS NOTES:
†
All voltages are 3 phase, 60 Hz.
Specifications can change without notice. Check with a Conair representative for the most current information.